Critical batch size under Muon optimizer
Doubling the training batch size eventually stops halving the number of steps to a target loss. McCandlish et al. called that point the critical batch size and proposed the gradient noise scale as a cheap proxy for it. Their derivation assumes a near-linear update, which Muon’s Newton–Schulz step is not.
I trained a 162M GPT-2 on FineWeb10B (in 124 e2e training runs in total) across:
- nine batch sizes,
- three momenta
- and a learning-rate ladder.
I then asked three questions:
- does Muon have a critical batch size? – yes
- does momentum move it? – yes, downward
- and does the noise scale still predict it? – no
The code and all logs are on github: